<?xml version="1.0" encoding="iso-8859-1" ?> 
<rss version="2.0">
<channel>
<title>Chemistry-Analyzer</title>
<link>http://www.sz-wholesale.com/rss/Chemistry-Analyzer.xml</link>
<description>Chemistry-Analyzer,Wholesale Chemistry-Analyzer</description>
<language>en-us</language>
<generator>Global Wholesale and Distribution Center</generator>
<item>
<title>chemistry analyzer</title>
<link>http://www.sz-wholesale.com/p/Chemistry-Analyzer/chemistry-analyzer-29087.html</link>
<description>¡¾Product category¡¿ Produrt¡¡¡¡Biochemistry analyzer  ¡¾Original manufactured in¡¿ Italy  ¡¾Product model number¡¿ Eos-bravo  ¡¾Product parameter¡¿ 180tests /hour      patent technique           The emergency sample can be inserted during the analyzing process without the limitation of the inserted quantity    The reagent refrigerating system is optional    The machine has the display function of curve response and quality control sketch ,which can monitor the whole process.    The instrument has the retest and automatic predilution function to the samples which show the abnormal results¡£    Multistandard predilution can be operated directly on the instrument,which avoid the error margin by the artificial dilution standard.    The instrument has the self examining function for the breakdown ,which is easy to maintain.    The instrument has open design, which can arbitrarily choose the imported or domestic reagents,such as single, double, three reagent to assembly ,also can adjust the parameter according to different reagent ¡£    Chinese-English operation interface     technology parameter         type: arbitrary choose /batch quantity autometic chemistry analyzer    Test method:end point, kinetic,two points, double wave-length, showing difference, double showing the color, dislinear multistandardization(Max up to 8 points)    Test speed:180 test/ hour    sample position:64 sample positions including standard , urgent, and controls     sample quantity: 5-100ul    Sample dilution:having the predilution function,which can autometicly retest the dilutioned sample .    Reagent position:18 reagent positions, the refrigerated system is selective.    reagent quantity:100-800ul    Reaction tray: 96 reaction cups in the hatch pond under temperature control,the hatch pond mix autometicly    Reaction total mount: 400-500ul    Reaction temperation: 37¡æ£¬¡À0.1     Light path system:efficient longevity halogen lamp,8 interfere optical filter£¬Wave-length coverage:340,405,490,510,546,578,620 and 700, go together with another two self choose vacancy, having the wave-length autometic zero control function,Photoelectic accuracy:1% of ¡À(0-2.5 scopes)    Dilution system:The precise dilution machine with the capacity of the 1000ul,increasing by the per ul, the error margin of which is smaller than 0.5%, combining the function of return to zero automatically.    Scaling:The eligibility scaling with 1-8 standards combining multistandards examination nonlinear samples    Programming memory: 64 testing procedure can be stored for a long period of time    Operate system:The Chinese management system includes the quality controls and statistics procedure, which can show and print scaling, kinetic, end point , detecting curve.Also have the function of batch detecting optimization and emergency detect setting.    Outlay:15" display, standard pc keyboard, printer    Interface: RS232 two-way interface</description>
</item>chemistry analyzer Wholesale, 
<item>
<title>chemistry analyzer</title>
<link>http://www.sz-wholesale.com/p/Chemistry-Analyzer/chemistry-analyzer-29072.html</link>
<description>¡¾Product category¡¿ Produrt¡¡¡¡Biochemistry analyzer  ¡¾Original manufactured in¡¿ ITaly  ¡¾Product model number¡¿ Eos bravo Forte  ¡¾Product parameter¡¿ 360tests /hour      OPERATIVE MODE: Innovative 3-plate coaxial structure; Random, Batch, STAT, Profile.ANALYTICAL MODES: Kinetics, end point (bichromatism option), fixed time, multistandard, graphical plot for all measurements, calculated mode.TROUGHPUT: 360 tests per hour, up to 420 tests with ISE unit (optional). SAMPLE POSITIONS: 118 sample positions; including normal ,emergency,control and standard SAMPLE VOLUME : 3-50ul SAMPLE PRE-DILUTION: auto pre-dilution for sample ,and retesting after the sample is diluted REAGENT POSITION: 70 reagent position ; refrigerated system temperature is 2 ¡æ -10 ¡æ REGEANT VOLUME: 10-400ul REACTION PLATE: 60 positions reaction plate. REACTION TOTAL VOLUME £º 100-500ul WASHING STATION: 8 needle cuvette washer, 1 piston pump cuvette drier, water consumption 500 ml/hour, automatic cuvette check before re-use. WAVELENGHT RANGE: 8 position filter wheel, automatic filter selection (340,405,492,505,546,578,630,700), other wavelenght available on request ISE UNIT : K,Na,Cl WASHING STATION: 10 steps cuvette washer, water consumption 500 ml/hour, automatic cuvette check before re-use. QUALITY CONTROL: Different controls can be defined for each test, Levey-Jennings graph, Westgards rules.ENVIRONMENT: Working temperature from 18 to 35¡ãC, relative humidity from 10 to 90%. SYSTEM INTERFACE: RS 232 serial interface bi-directional for remote access. DIMENSIONS (FLOORSTANDING): (W)70 x (D)65 x (H)120;</description>
</item>chemistry analyzer Wholesale, 
</channel>
</rss>