High Temp Load Cells Description
All loadcells have output spans that change with temperature. This causes significant measurement errors particularly if the loadcell is required to operate over a wide temperature range. The currently used method for compensating for this error in strain gauged loadcells is to use nickel or Balco foil resistors in series with the sensor excitation connections. The method is limited in accuracy by the non-linearity of the resistance change of the foil resistors with temperature. This non-linearity increases at temperatures above 10045123 and foil resistors are not suitable for use at temperatures above 20045123.Novatech's new invention compensates for loadcell output span changes with temperature by using passive temperature sensitive elements in the bridge circuit. The temperature coefficient of the temperature sensitive elements is adjusted to be the inverse of the sensor's uncompensated span change with temperature. Accurate linear compensation can be achieved over a temperature range of -50 to 25045123.
This method is inherently more linear than traditional methods that employ nickel or Balco resistors in series with the sensor excitation connections, giving performance specification several times better on span (typically 0.0025% output/45123) than most other load cells currently available for high temperature use. With additional trimming over a range of temperatures of particular interest we would expect to achieve <0.001% output/45123.
Novatech has an international patent application pending for this novel approach to high temperature modulus compensation, currently available on 70% of Novatech products.
Exporters, Suppliers, Manufacturers,
Factories,Distributo,Wholesale High Temp Load Cells China, Exporters,Custom printed
High Temp Load Cells Related Resource
other 5 Other 4 Other 2 Other 1 High Temp Load CellsHigh Temp Load Cells Related Products
A
| B | B11
| C | C11
| C21 | D
| E | F
| G | H
| I | J
| K | L
| M | M11
|N | O
| P | P11
| Q | R
| S | S11
| S21 |
T | U | V
| W | X
| Y | Z
High Temp Load Cells
OK CHINA INDUSTRIAL LTD
Add:Room 601, Friendship Base Bld,West of Xixiang Road, Baoan District,Shenzhen
China
Tel:+86-755-27906922 , 27910156, 27908665, 27906017 , 27903622 , 27792188
, 27902868, 27917039 , 27917519
FAX:+86-755-27905633
E-Mail: sale@sz-wholesale.com
Finland Office:
Mr. Matti, E-mail: Maserholz@scand.inet.fi
Copyright © sz-wholesale.com
2002
High Temp Load Cells China,Custom printed
High Temp Load Cells